HandKey II Manual
71
26 25 24 23 22
21 20 19 18
17
16
15 14 13 12 11 10
9 8
7
6 5 4
3 2
1
4-Wire
RS-422
Connection
12 to 24 V
AC/DC
Input
+
-
* These components are not supplied by Schlage Biometrics, Inc.
TOP OF THE
HAND READER
WALL TO WHICH
THE HAND READER
IS ATTACHED
AUX OUTPUT 2
AUX OUTPUT 1
AUX OUTPUT 0
AUX INPUT 2 **
AUX INPUT 1 **
N.C. DOOR SWITCH
REQUEST TO EXIT
SWITCH LEGEND
N.O. MOMENTARY*
N.C. DOOR SWITCH*
GROUND
DATA 1
DATA 1
GROUND
DATA 0
DATA 0
+5 VDC POWER
(SEE NOTE BELOW)
NOTE: For +12 VDC readers, connect power supply +12 VDC to card reader.
Access Panel
Card Reader
** The operation of the Auxiliary Inputs depends upon how the inputs have been configured.
Figure 19-11: Card Reader Emulation Mode Wiring Diagram